Hemostasis Reference Laboratory

Factor XII Activity

  • Transaction Code: 3210-17
  • CPT Code (Suggested): 85280

A one-stage intrinsic system clotting assay is used to measure circulating factor XII levels. Clotting times of dilutions of patient plasma are compared to dilutions of a plasma pool from normal donors, when added to deficient plasma. [Levels are reduced in hereditary factor XI deficiency (which is sometimes associated with a clinical bleeding tendency), or in the presence of a factor XI inhibitor, liver disease, or disseminated intravascular coagulation (DIC).]

  • Sample Required: 0.5 ml frozen plasma x4 or (2) 3.2% sodium citrated tubes, 5 ml each.
  • See Sample Requirements when ordered with other tests.
  • Normal Range: 60-170% effective 11/1/11
  • Analytic Time: Performed weekly, available STAT
  Questions: 206-292-6594